TY - JOUR ID - 4830 TI - Simulation of Temperature Distribution in a Continuous Tunnel Reheat Furnace Using the Monte Carlo Method JO - International Journal of Iron & Steel Society of Iran JA - IJISSI LA - en SN - 2981-0388 AU - Safari, M. AU - Saboonchi, A. AD - Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran Y1 - 2008 PY - 2008 VL - 5 IS - 1 SP - 1 EP - 7 DO - N2 - A mathematical model of a continuous reheating furnace has been developed to identify the design and operating parameters that significantly affect furnace performance. In this study, the furnace is modeled 3 dimensionally and theMonte Carlomethod is used to find the overall absorption factor. The overall absorption factor is then used to calculate the energy balance for furnace walls, the gas, and the moving slab. For this purpose, 1-D heat conduction in walls and 2-D heat transfer in the slab are assumed. Results include temperature distribution of gas, walls, and slab. The effects of emissivity of slab and furnace height on the efficiency of furnace are also analyzed. It is concluded that operating efficiency increases by increasing load emissivity and by decreasing furnace height. UR - https://journal.issiran.com/article_4830.html L1 - https://journal.issiran.com/article_4830_64422553aa32ce92a5a1b939a039d424.pdf ER -